1.0 INTENDED USE
The SRPM is designed to monitor critical environments by providing
differential pressure indication. Typically this is between a monitored
room and a reference space such as a corridor or ante room. The unit
also provides monitoring, alarm and communications functions.
Installation must be indoors, Polution Degree 2, Installation Category II.
Typical Applications:
1. Hospitals
– patient isolation and protection rooms, operating
suites, intensive care, and emergency rooms.
2. Pharmaceutical, semiconductor, precision manufacturing, and
clean rooms.
3. Laboratories
– medical research, BSL (Bio safety labs), radiation,
vivarium, toxic metals and chemicals. Indoor use only.
1.1 SPECIFICATIONS
Service: Air or nonconductive, nonexplosive gases.
Accuracy: ±0.5% F.S., ±0.25% FS optional
Operating Temperature Limits: 32 to 120°F (0 to 50°C).
Operating Humidity Limits: 5 to 95% Relative humidity
(non-condensing).
Altitude: 2000 meters (max).
Thermal Effects: ±0.03% F.S./ °F (± 0.05% F.S./ °C).
Overpressure: ±15” WC.
Supply Voltage:
Code V1 and V2 85-265 VAC, 50-60 Hz
Code A1 and A2 18-32 VAC, 50-60 Hz.
Power Consumption (Voltage output): 5 W.
Output: Selectable 4-20 mA (2-wire), 0-5 VDC (3-wire), or 0-10 VDC (3-
wire).
Loop Resistance (4-20mA output): 0-510 OHMS Ω.
Electrical Connection: Removable terminal block.
Pressure Fittings: Barbed fi ttings for 1/4” O.D. tubing.
Housing: Fire retardant plastic (NEMA 1, IP20 rated for indoor
applications).
Mounting: Mounts to customer supplied 4½ x 4½ plaster ring (mounts to
double gang electrical box).
Dimensions: 8½ H x 5.4½ W x 1.8½ D (20.3 H x 13.7 W x 4.1
Weight approx.): 1.5 lbs (680 g).
Agency Approval: CE
,
CAN/CSA-C22.2 NO. 61010-1-04
Communications: BACnet MSTP ASC, optional, see setra.com for
detailed PICS statement.
Zobrazit stránku 3
1 2 3 4 5 6 7 8 9 ... 27 28

Komentáře k této Příručce

Žádné komentáře

Paradyne T1 T1 Access Mux 926x manuels

Manuels d'utilisation et guides de l'utilisateur pour Matériel Paradyne T1 T1 Access Mux 926x.
Nous fournissons des manuels en pdf 1 Paradyne T1 T1 Access Mux 926x à télécharger gratuitement par type de document : Manuel de l'utilisateur


Table des matières

MODEL 916x/926x

1

T1 ACCESS MUX

1

Printed on recycled paper

2

WARNING:

3

Important Safety Instructions

4

Government Requirements

5

United States

5

CAUTION:

6

Contents

7

4 User Interface

8

5 Setting Up

8

6 Security

9

8 Operation and Maintenance

10

9 Troubleshooting

11

9161-A2-GH30-30

12

April 1998

12

B IP Addressing

13

C SNMP Traps

13

D SNMP Cross-Reference

13

F Technical Specifications

14

G Equipment List

14

Glossary

14

About This Guide

15

Conventions Used

16

Product-Related Documents

17

Reference Documents

18

About the T1 Access Mux

19

Components

20

Fully Loaded 5-Slot Housing

21

Fully Loaded Access Carrier

21

Features

24

Menu-Driven User Interface

25

Embedded Data Link (EDL)

26

Direct Data Link (DDL)

26

Facility Data Link (FDL)

26

COM Port

26

Management and Control

29

496-15182

30

496-1518

32

Applications

35

Drop & Insert

40

Off-Premises Extension (OPX)

42

Direct Inward Dial (DID)

42

Video Conferencing

43

Screen Field Types

46

What Affects Screen Displays

47

Screen Work Areas

47

Screen Format Description

48

Navigating the Screens

49

Screen Function Keys

50

Selecting from a Menu

51

Selecting a Field

51

Making Input Selections

51

Accessing the User Interface

52

Setting Date and Time

58

Configuration Option Areas

59

Saving Configuration Options

60

 FDL does not appear if:

64

Configuring Ports

70

Configuring Voice Ports

78

For FXO Voice Ports:

80

 Wink Delay only appears if:

81

For FXS Voice Ports:

83

Configuring OCU-DP Ports

86

Copying Port Configurations

89

Example Channel Allocation

92

Assigning OCU-DP Data Ports

100

" Procedure

100

Clearing Port Assignments

101

Setting System Options

102

Setting Up

103

User Interface

106

Communication Port Options

106

Configuration Edit/Display

106

External Device

111

Control Characters

114

Sequence ASCII Hex

114

 Procedure

115

Management and Communication

121

Communication Protocol

121

SNMP Management

124

Setting Up SNMP NMS Security

126

Setting Up and Placing a Call

132

Security

133

Procedure

134

Limiting Telnet Access

135

Controlling SNMP Access

137

Creating a Login

140

Deleting a Login

141

Displaying System Information

143

Displaying Voice APM Status

145

Displaying Network Channels

149

 failed

150

Displaying DSX-1 Channels

151

Displaying Port Assignments

153

Statistics

154

Status Information

158

System Status Messages

158

Health and Status Messages

159

What It Indicates What To Do

160

Test Status Messages

166

Message What It Indicates

167

Operation and Maintenance

169

Logging Out

170

Starting a Session

170

Ending a Session

172

Supported SNMP Traps

173

 Call Retry to Enable

174

Displaying Directory Numbers

174

Changing Device Name

175

Hot Swapping of APMs

176

NAM Removal

177

Downloading Software

177

File Transfer

177

Performing an Upgrade

178

Backing Up Your Configuration

180

Resetting the T1 Access Unit

181

Troubleshooting

183

496-15051

184

 Loss of Signal (LOS)

185

 Loss of Frame (LOF)

185

 Excessive Error Rate (EER)

185

 Yellow

185

T1 NAM Test Jack Functions

186

Test Jack Name Function

187

Test Jacks

189

Test Jacks

190

9109 SYNC DATA

191

OCU-DP APM Front Panel LEDs

192

Voice APM Front Panel LED

193

System Alarm Relay

193

ASCII Alarm Messages

194

System Error Messages

200

Tests Available

203

Interface Tests

204

Remote Loopbacks

208

Data Port Tests

210

Voice Port Tests

214

Digital Loopbacks

215

Analog Loopbacks

215

Force and Monitor Signaling

217

OCU-DP Tests

219

OCU-DP Local Loopback Tests

220

98-15958

221

OCU-DP Remote Loopback Tests

224

Device Tests

224

Test Timeout

225

Starting and Stopping a Test

225

Aborting All Tests

226

Menus and Configuration

227

Worksheets

227

Configuration

228

Recording Configurations

229

Network See Table 5-1

230

Configuration Option Settings

230

DSX-1 See Table 5-2

231

Default in [Bold]

232

Voice Ports

233

E&M Voice See Table 5-4

233

FXO Voice See Table 5-5

234

FXS Voice See Table 5-6

235

OCU-DP Ports See Table 5-7

236

Default in

238

Assigning Cross Connections

241

9161-A2-GH30-30April 1998

244

IP Addressing

245

IP Addressing Scheme Examples

247

If using . .

251

Then . .

251

SNMP Traps

253

Trap: authentificationFailure

254

Traps: linkUp and linkDown

254

Traps: Enterprise-Specific

256

SNMP Cross-Reference

259

User Interface Command

260

SNMP MIB Object

260

Cables, Connectors, and Pin

275

Assignments

275

COM Port-to-Modem Cable

277

Gender Adapter/Changer

277

T1 Network Interface Cable

278

DSX-1 Port Interface

279

T1 Line Interface Cable

279

EIA-530A Port Interface

280

25-Pin Plug

281

Connector

281

12 Inches

281

34-Position Socket

281

DTE’s RS449 connector

283

496-1514

285

Voice APM Cables

286

E&M Voice APM Connector

287

Port SignalFunctionPin

288

Extension Cables

289

97-15171-02

290

97-15172-02

292

P1 Pin #

293

P2 Pin #

295

P3 Pin #

297

OCU Port

299

T1 Mass Termination Cable

300

Technical Specifications

301

Specification Criteria

302

Equipment List

309

Equipment Feature Number

310

Yellow Alarm

316





Plus de produits et de manuels pour Matériel Paradyne

Modèles Type de document
COMSPHERE 3600 Series Manuel de l'utilisateur   Paradyne COMSPHERE 3600 Series User Manual, 53 pages
UIM-1000T Manuel de l'utilisateur   Paradyne UIM-1000T User Manual, 4 pages
COMSPHERE 3611 Manuel de l'utilisateur   Paradyne COMSPHERE 3611 User Manual, 81 pages
BitStorm 2600 IP DSLAM Manuel de l'utilisateur   Paradyne BitStorm 2600 IP DSLAM User Manual, 58 pages